메뉴전체보기
메뉴전체보기 닫기
견적문의 게시판좌측배너
History
찾아 본
상품이
없습니다.

ATEC-CONTAu
페이스북 트위터 이메일
상품평점(총 0건) 0 상품평 더보기
ATEC-CONTAu
Gold Coated Contact Mode AFM Probe with REAL Tip Visibility
총 결제금액
(부가세포함)
0
이 상품을 장바구니에 담았습니다.
지금 장바구니를 확인하시겠습니까?


AFM/SPM PROBE

(원자현미경/주사탐침현미경 탐침)



  Product Description

NANOSENSORS™ AdvancedTEC™ ContAu AFM probes are designed for contact mode imaging. They feature a tetrahedral tip that protrudes from the very end of the cantilever.

This unique feature allows precise positioning and makes the AdvancedTEC™ the only AFM scanning probe in the world that offers REAL TIP VISIBILITY FROM TOP, even when the probe is tilted due to its mounting onto the AFM head. This feature makes them the premium choice for all applications where the tip has to be placed exactly on the point of interest and/or has to be visible (e.g. Nanomanipulation).

Due to their very small half cone angles the tips of the AdvancedTEC™ Series show great performance on samples that have a small pattern size combined with steep sample features.

The probe offers unique features:

REAL TIP VISIBILITY FROM TOP

metallic conductivity of the tip

high mechanical Q-factor for high sensitivity

aspect ratio of the last 1.5 µm of the tip > 4:1 (from front and side)

tip shape is defined by real crystal planes resulting in highly reproducible geometries and extremely smooth surfaces

highly doped single crystal silicon (0.01-0.025 Ohm*cm)

rectangular cantilever with trapezoidal cross section

holder dimensions are 1.6 mm x 3.4 mm

It is compatible with:

Bruker / Veeco / Digital Instruments

Keysight / Agilent / Molecular Imaging

Asylum Research

Park Systems

JEOL

JPK

etc.

 
  Coating Description

The Au coating is an approximately 70 nm thick double layer of chromium and gold on both sides of the cantilever.

The tip side coating enhances the conductivity of the tip and allows electrical contacts.

The detector side coating enhances the reflectivity of the laser beam by a factor of about 2 and prevents light from interfering within the cantilever.

The coating process is optimized for stress compensation and wear resistance. The bending of the cantilever due to stress is less than 3.5% of the cantilever length.

  AFM Tip
Shape   Visible  
Height   17um (15-20um)  
       
  AFM Cantilever
Shape   Beam  
Length   450um (440-460um)  
Width   50um (45-55um)  
Thickness   2um (1-3um)  
Force Constant   0.2N/m (0.02-0.75N/m)  
Resonance Frequency   15kHz (7-25kHz)  
       


상품정보에 배송/교환/반품 및 취소와 관련된 안내가 별도 기재된 경우 ,아래의 내용보다 우선하여 적용됩니다.
판매자정보
상호명
(주)프로브스
대표자
김용균
사업자등록번호
215-87-50331
통신판매업번호
제2017-서울송파-1811호
대표전화
070-7836-5319
팩스전화
02-6280-5319
이메일
  이메일: probes.ykkim@gmail.com
개인정보취급책임자
김용균,  호스팅업체: 원데이넷,
사업장소재지
서울특별시 송파구 법원로 90, 파트너스 2, 503호
배송/반품/취소/교환안내
지정택배사
기본배송비
배송비 5,000원 (100,000원 이상 무료배송)
평균배송기간
배송등록 후 2-3일
반송주소
서울특별시 송파구 법원로 90, 503호(문정동 파트너스2)
교환/반품/환불이 가능한 경우
  • 제품 하자의 경우 전화로 해당 건에 대해 설명과 함께 하자에 대한 내용을 메일로 사진과 함께 남겨주십시오.
  • 제품 하자 이외 단순 변심에 의한 교환/반품은 불가합니다.
  • 제품 수령 후 제품의 이상 유무를 7일 이내 확인해 주십시오.
교환/반품/환불이 가능한 경우
  • 반품/교환 요청기간이 지난 경우
  • 구매자의 책임 있는 사유로 상품 등이 멸실 또는 훼손된 경우 (단, 상품의 내용을 확인하기 위하여 포장 등을 훼손한 경우는 제외)
  • 구매자의 사용 또는 일부 소비에 의하여 상품의 가치가 현저히 감소한 경우
  • 오랜 시간의 경과로 제품의 이상 유무를 확인하기 어려운 경우

고객센터
070-7836-5319 09:00 ~ 18:00 주말 및 공휴일은 휴무입니다. Email : probes.ykkim@gmail.com 입금계좌[신한은행]전화문의 후 번호확인
(주)프로브스